Applications
PowerStream High Pressure Coolant Systems

HEAT

Properly applied coolant absorbs much of the heat generated in the cutting zone. High pressure coolant enables more effective cooling which allows a higher metal removal rate which, in turn, results in more heat transferred to the coolant. A high pressure pump may also introduce heat to the coolant. In some cases, the process dictates the use of an external cooling mechanism. Turbo’s ‘clean coolant’ reservoir provides an effective heat dissipation mechanism. This eliminates the need for additional cooling equipment in many cases.

 
Performance Characteristics (Standard System)
Filtration 10um standard. 5 to 200 optional.
Transfer / Filtration Flow 12-15 gpm
Transfer Pressure < 25 psi
High Pressure Flow 8 gpm
Maximum Pressure 1000 psi
Control Input machine tool m-codes to suit user
Control Output 24 VDC or 110 VAC signals

Consult Factory For Other Pressures Flow Rates and Capacities.